Theta 107 HT...
Back to Home
Welding Electrodes5 min readDiperbarui: 16 Mei 2026

Preventing Hydrogen Cracking in Heavy Equipment Chassis Welding

Explanation of why cold cracking often appears in high-strength steel welding, how to control hydrogen vapor, and the real benefits of 7018 electrode wires.

In critical structural applications, such as the joining of harbor gantry cranes, mining machinery frames, or heavy bulldozer chassis assembly, the integrity of the plate joints determines the work safety margin. The biggest threat that cannot always be spotted by mechanical eyes is connection failure after cooling, known as Hydrogen Induced Cold Cracking (HIC).

Anatomy of the Hydrogen Cracking Disaster

This type of cracking occurs in High Strength Carbon Steel and Low Alloy steel hours—to even weeks—after the welding procedure is finished in ambient temperature. 3 components must exist for this crack bomb to occur:

  • Presence of Hydrogen Gas in the liquid arc zone.
  • Martensite Microstructure / brittle-remnant that solidifies very hard in the Heat Affected Zone (HAZ).
  • High Residual Stress from contraction pressure of sudden stiff iron shrinkage and rigid mechanical structure clamping.

Sources of Hydrogen Leakage: Moist Air and Hand Execution

If you weld outside a sheltered workshop or do not dry your iron dust flux intake... Moisture (H2O air) on the coating flux will dissociate in the intense arc into single free hydrogen cells. Those micro atoms wander into metal pores, forcing shrinking metal spaces and "REBREAKING - CRACKING" from the inside.

Prevention: 7018 Low Hydrogen Wire

The ISO/AWS technical solution is abandoning standard titanium home wires (like AWS E6013), switching absolutely to tested trigger flux mix with Thetaindo E7018 specifications.

Chassis Plate Protection MethodStandard AWS Execution Detail
Use E7018 Electrodes (Zieta Steel line)Type 7018 is engineered with a calcium carbonate silicate layer for extreme hydrogen control to protect extra high-tensile 70,000 psi steel from microscopic cracks.
Daily Baking Heat Oven (Rod Quiver)For super-heavy safety in shipyards / mines, do not unpack flux wires carelessly. Heat electrodes in a special oven (~120-150 °C) to remove all hydrogen dew and flux film vapor, PRECISELY before the welder acts.
Pre-Heating Steel MetalSpray torch fire on the iron blocks (pre-heat to 200°C). This slows down sudden HAZ zone cooling, allowing steel to cool slowly to release Hydrogen diffusion out without shear fracture force.

Caterpillar / Scania mining excavator maintenance requires extra welding protection. Contact Zieta industrial engineers for 7018 iron versatile mill test certification.